Powering critical infrastructure for a resilient future.

Merry Christmas from Bluecircle

While you celebrate Christmas, we secure the power supply.

Round-the-clock service, 24/7/365 – even when operations run on minimum staffing over Christmas.

Welcome to Bluecircle

We look after the power, so you can look after operations.

With us you talk to specialists who stand by the systems themselves. We help facility managers and IT managers keep critical operations running – from the first conversation to many years of service.

Gabriell Summerland

Gabriell Summerland

CEO · Authorised electrical contractor

What happens when the power goes – not for hours, but days? Do you have a plan?Let us make it together

We operate where failure is not an option — delivering the assurance, documentation and technical precision required to keep critical infrastructure online.

Ensuring continuity when it matters most.

Resilience

The link between business, IT and critical infrastructure

The CER Act enters into force in

200days

17 June 2027

Is your organisation ready for the CER Directive?

The EU CER Directive (EU) 2022/2557 sets new requirements for companies and organisations that operate critical services.

It is not just about understanding risk – but about documenting resilience, preparedness and the ability to maintain operations when serious incidents strike.

The CER Act's requirements for critical entities

  1. 01Risk assessmentThreats and dependencies
  2. 02ResilienceTechnical and organisational measures
  3. 03Preparedness planOperation during serious incidents
  4. 04Incident reportingFirst notification within 24 hours

Resilience

Get a technical assessment of your preparedness plan

We review your plan technically and assess whether RTO, restart and backup power architecture work together in practice.

  • RTO – how quickly operations must be back
  • Restart after a power failure
  • Emergency power architecture

See how Bluecircle works with business continuity plans, risk management and resilience.

We update your business continuity plan so it matches the required security level.

Critical Power

Where resilience becomes infrastructure.

Stratus Power from Centiel – 750 kW modular, energy-efficient UPS systemModular UPS systems Stratus Centiel

Site Secured

ModularModular static UPS systems made in Switzerland

verified
Site Secured
Stratus Power SP750T UPS system

Energy savings from DKK 27,810 in one year.

Hot-swap power modules

Site Secured

UPS modules with 97.6% efficiency

Stratus Power UPS module SM-M 50 kW

From 10 kW to 3.75 MW

A modular design that delivers unrivalled reliability, uptime, efficiency and serviceability.

  • Design life of more than 30 years
  • Components that need no replacement for 15+ years
  • The modules provide 24% extra capacity
  • Triple-mode parallel bus adds an extra layer of redundancy
Stratus Power UPS module SM-M 50 kW

UPS selector

Do you know what you need – but not which system?

Enter the load and required autonomy, and the UPS selector finds the systems and battery configurations that fit. You see the lowest-cost solution first and can build up from there.

Find your UPS system

Site Secured

Rotary UPS systems: What do dynamic emergency power solutions do?

RUPS & DRUPS systems with +30 years of service life & limited use of wear parts.

+30 years
Service life
RUPS & DRUPS
Rotary and diesel rotary UPS
Few wear parts
Limited use of wear parts
Hitec PowerPRO 2700 rotary UPS
Drilling platform and supply vessel in the North Sea at dusk

Ship Secured

UPS systems for Marine & Offshore

UPS systems for particularly aggressive environments such as offshore, oil and gas and more.

Marine UPS systems
DNV, Lloyd's Register and RINA

Certification available from global accredited certification bodies

Site Secured

A generator set no longer has to emit CO2 and harmful particles. We have an alternative that emits only heat and water.

Alternative to the diesel generator

HyFlex™ hydrogen generator

HyFlex™ is a zero-emission generator that produces electricity, heat and water.

  • Electricity
  • Heat
  • Water
HyFlex™ fuel cell generator
1 MVA diesel generator at full load
225kg diesel per hour
The same diesel generator
720kg CO2 per hour
HyFlex™ emits only heat and water
0kg CO2 per hour

Assurance

From engineered intent to verified performance.

Commissioning phase 2–4

Interim & Final Commissioning

We carry out independent testing and verification of critical systems in commissioning phases 2–4, based on recognised data centre processes. This ensures validation across function, integration and operation towards go-live.

Point at a system in the server room to see what we test.

Interactive platform

Interactive server room with UPS, cooling and electrical infrastructure

From component to integrated operation

See how we carry out commissioning from Level 2 to IST – and what we test along the way.

Load testing and integrated systems testing require a load that can be controlled precisely. That is why we also supply load banks for the job.

Assurance

Round-the-clock operational readiness.

Bluecircle delivers tailored solutions based on technical expertise, with short lead times.

Our experienced team provides on-site support and ensures stable operation and high availability.

Load bank test at Helsingør CHP plant

No task is too big

We offer Europe's largest fleet of test equipment, including load banks.

Choose Bluecircle for load bank testing – fast, reliable and tailored to your needs.

Rental of load banks for critical infrastructureResistive and DC load banks for load testing generators, UPS and critical infrastructure. Used for commissioning, testing and verification under controlled conditions.See load banks
Container load banks connected with heavy cable runs at a data centre

Assurance

Certified electrical thermography in critical infrastructure

Bluecircle delivers thermographic documentation as an integral part of Level 3 commissioning.

Thermal camera showing a thermal image of a switchboardTechnicians measuring on switchboards during commissioningDBI-certified thermographer measuring on a switchboardDBI
    1. 01DS/HD 60364 (electrical installations – operation and maintenance)
    2. 02EN 50110-1 (operation of electrical installations)
    3. 03NFPA 70B (thermographic inspection principles and ΔT assessment)
  1. Thermographic verification during Level 3 and IST.

    The documentation forms part of the overall commissioning verification and can be used for both internal QA and external audit.

  2. Extensive experience in thermal verification of critical installations, including:

    • MV transformers
    • Busbar trunking and switchboard busbars
    • UPS systems
    • Generator sets
    • Tap-offs and penetrations
    • Other live components in mission-critical environments

Cx Live

Cx Live – Virtual thermographic documentation platform in real time

Cx Live is our in-house commissioning platform.

During the load test, the Cx Lead and Project Owner get direct access to all thermal measuring points in real time.

  1. Cx Live measurement point card with thermography, measured values and classification

    Live

    Each measuring point shows all relevant audit-ready data for a fast, precise assessment.

  2. Cx Live virtual thermographic documentation in real time

    Live

    The Cx Lead and Project Owner follow every thermal measuring point live – while the test is running.

  3. Cx Live thermography at Bluecircle

    Live

    Reports are generated continuously. When the test is complete, compliance is already documented.

Contact us for more information about Cx Live.

Contact Bluecircle

Continuity

Assured performance. Sustained resilience.

Service

UPS audit, service and battery testing

Bluecircle technician with equipment case arriving for a UPS auditTesting UPS batteries with a DC load bankService technician arriving for UPS service
  1. Let us take the "temperature" of your UPS setup, review the infrastructure and UPS systems, and assess whether everything is as you expect.

  2. Without disturbing the UPS or discharging the batteries unnecessarily.

  3. We install, test and maintain UPS systems with a focus on documented reliability.

    1. 01Verified performance under load
    2. 02Systematic review of the backup power chain
    3. 03Focus on redundancy, autonomy and selectivity

Continuity

Cleanliness in server rooms and data centres – measured and documented

We document cleanliness, environmental control and compliance with traceable measurements, clear deviations and audit-ready reports – so the foundation is secure before operation begins.

ISO 14644-1
Classification of air cleanliness
ISO 21501-4
Calibrated particle counters
GMP / GxP
Cleanroom control and documentation