Continuity · Particle Control

ISO 14644 Particle Control

A particle counter in a room gives you a number. ISO 14644 turns that number into documentation: the right class, the right sampling locations, the right occupancy state and a plan that detects changes in time. We classify, find the sources and build the monitoring that keeps particle levels under control in operation.

9
Cleanliness classes in ISO 14644-1, from ISO Class 1 as the cleanest to ISO Class 9
24
Sampling locations is the minimum for a room of up to 352 m² according to Table A.1
3
Occupancy states: as-built, at-rest and operational
2 litres
Minimum sample volume per location, sampled for at least 1 minute

The standard

What is ISO 14644?

ISO 14644 is the international series of standards for cleanrooms and associated controlled environments. Part 1 classifies air cleanliness by the concentration of airborne particles at specified particle sizes.

The series covers the whole life of a controlled area: from design and start-up through classification and testing to monitoring and daily operation.

  1. BuildISO 14644-4: design, construction and start-up
  2. ClassifyISO 14644-1: cleanliness class by particles
  3. TestISO 14644-3: test methods for performance
  4. MonitorISO 14644-2: evidence of performance over time
  5. OperateISO 14644-5: requirements for daily operation
The parts of ISO 14644 used most in particle control
PartSubjectUsed for
ISO 14644-1:2015Classification of air cleanliness by particle concentrationThe class, sampling locations and sample volume
ISO 14644-2:2015Monitoring to provide evidence of cleanroom performanceThe monitoring plan in operation
ISO 14644-3:2019Test methodsInvestigating airflow and filters, for example
ISO 14644-4:2022Design, construction and start-upNew and rebuilt areas
ISO 14644-5:2025OperationsBehaviour, cleaning and materials in daily operation
ISO 14644-8:2022Air cleanliness by chemical concentrationChemical air contamination
ISO 14644-9:2022Surface cleanliness by particle concentrationParticles on surfaces
ISO 21501-4Calibration of airborne particle countersThe particle counter used for the measurement

Cleanliness classes

Nine classes, each ten times cleaner

The class states the maximum permitted number of particles per m³ of air at the particle sizes included in the measurement. The limits are cumulative, so the figure at 0.5 µm includes all particles of 0.5 µm and larger.

From one class to the next, the limit changes by a factor of ten. ISO Class 8 therefore permits ten times as many particles as ISO Class 7.

Particles ≥ 0.5 µm per m³, logarithmic scale

  • ISO 53,520
  • ISO 635,200
  • ISO 7352,000The case
  • ISO 83,520,000Typical in data centres
  • ISO 935,200,000
Each step on the scale is a factor of ten.
Limits in ISO 14644-1:2015, particles per m³
Class≥ 0.5 µm≥ 1 µm≥ 5 µm
ISO Class 53,520832Not specified
ISO Class 635,2008,320293
ISO Class 7352,00083,2002,930
ISO Class 83,520,000832,00029,300
ISO Class 935,200,0008,320,000293,000
Cn

The limits are calculated as Cn = 10N × (0.1/D)2.08, where N is the class and D the particle size in µm. Intermediate classes can be specified in steps of 0.1. ISO Class 9 applies only in the operational occupancy state.

In data centres, ISO Class 8 is the usual target after technical cleaning. Read more under data centre and server room cleaning.

Classification

The test basis is set before the measurement

Two particle measurements can only be compared if the sampling locations, the instrument, the occupancy state and the activity are known. That is why the test basis is agreed before the particle counter is switched on.

The number of sampling locations follows from the area of the room. Their placement is set according to the layout, and critical spots can require extra locations.

  • State 1As-built

    The installation is complete, with all services connected and running. No production equipment, no materials and no people.

  • State 2At-rest

    The equipment is installed and running as agreed, but there are no people in the room.

  • State 3Operational

    The room is in operation with the agreed staffing and activity. The hardest state to pass.

ABC
  • Classification location (24)
  • Diagnostic location: A airlock, B packing station, C assembly station by a door
Example: a production area of about 300 m² divided into 24 equal grid cells with one sampling location in each.
Minimum number of sampling locations by area, extract from Table A.1 in ISO 14644-1:2015
Area up toLocations
10 m²5
24 m²6
52 m²10
104 m²16
148 m²19
232 m²22
352 m²24
636 m²26
1,000 m²27
Airborne particle counter on a tripod in an aisle between server racks
Samples are taken at working height, and the particle counter must be calibrated to ISO 21501-4.
What is recorded with each measurement
RecordWhy
Date and timeThe measurement can be compared with operation and cleaning
Occupancy stateAs-built, at-rest and operational give different levels
Number of peoplePeople and their movements add particles
Activities and door openingsFluctuations can be linked to what was going on
Cleaning and deviationsExplains single measurements that stand out
Sample volumeAt least 2 litres and 1 minute per location, more for cleaner classes

The case

From inconsistent measurements to a pattern

An electronics manufacturer saw a growing number of faults during assembly of sensitive components. The area had filtered air, access rules and fixed cleaning routines, but nobody could say whether airborne particles were a contributing cause.

The aim was to document the area to ISO Class 7 and keep particle control in place during normal production.

About the caseThe case is an illustrative, anonymised process. Company, measurements and results are constructed examples, not documented customer data. It shows how a project can be organised according to the principles of ISO 14644.

  1. 01Fixed methodA consistent classification method
  2. 02LocationsRepresentative and critical spots
  3. 03CausesConditions that explain high readings
  4. 04ImprovementsChanges and repeat measurements
  5. 05MonitoringA plan that detects changes in time
The test basis in the case
ItemChoice in the caseWhy
ClassISO Class 7The requirement for assembly of sensitive components
Particle sizes0.5 µm and 5.0 µmFine particles and the larger ones that typically come from activity
Sampling locations24 distributed locations and 3 diagnostic locationsTable A.1 for about 300 m² plus airlock, packing station and an assembly station
Occupancy statesAt-rest and operationalThe difference shows what operation itself adds

Baseline: the fluctuations followed specific activities

Most locations were stable at 0.5 µm, but in some places the concentration rose clearly during operation: at the packing station when packaging was opened, at the airlock when materials were moved in, at an assembly station near a frequently used door and shortly after dry cleaning of a work surface. The figures are fictitious and not a classification report.

Typical levels during operation in the case, particles per m³
Area0.5 µm5.0 µmObservation
Assembly stations away from doors125,000–210,000300–1,500Mostly stable values
Packing station180,000–310,0001,200–3,600Short peaks when packaging is opened
Airlock and material route160,000–280,0001,000–3,300Fluctuations with transport and door openings
Assembly station near door170,000–290,0001,100–3,400Raised level with simultaneous traffic
2,930

The 5.0 µm limit for ISO Class 7. Three of the four areas exceeded it at their peaks. The pattern did not point to failing filtration of the whole room, but to material flow, work methods and local air movement.

  • Packaging and materials

    Packaging was opened close to the product, and some materials shed visible fibres.

  • Traffic through the airlock

    The door was sometimes held open while pallets and trolleys were moved through.

  • Cleaning method

    Dry cloths and quick movements can lift particles into the air instead of removing them.

  • Air distribution

    Air movement and ventilation were investigated as explanations for local fluctuations, using test methods from ISO 14644-3.

Improvements

Measures that can be measured one by one

The improvements were chosen because they could be linked directly to the observed fluctuations. That way the effect can be measured, instead of introducing general measures and hoping for the best.

Afterwards, the measurements were repeated with the same locations, the same staffing and comparable activity.

Technician in cleanroom garments vacuuming the floor with a HEPA-filtered vacuum cleaner
Dry wiping was replaced by a cleaning method suited to the controlled area.
The improvements in the case
AreaMeasures
Material handlingPackaging opened in a separate zone away from assembly, waste removed continuously in closed containers, and materials wiped to a fixed procedure before entry
Airlock and trafficConsolidated deliveries, separate flows for people and materials, never both airlock doors open at once, and fixed cleaning of trolleys
Cleaning and behaviourNew cleaning method, instruction in work movements, cleaning outside sensitive activities and recording of deviations
Technical reviewAir distribution, filters and air supply assessed, and critical locations compared with the workstations

Particles ≥ 5.0 µm per m³ during operation, before and after

  • Assembly stations away from doors
  • Packing station
  • Airlock and material route
  • Assembly station near door
  • Before improvements
  • After improvements
  • Limit for ISO Class 7
The figures are fictitious and illustrate the pattern in the case.
Overall

The results were assessed across all locations and operating conditions, so that one good measurement did not hide a recurring problem with a specific activity.

Monitoring

From classification to continuous control

A classification documents the conditions during one measurement. It does not show that the area still meets the class when processes, staffing or equipment change.

ISO 14644-2 describes the minimum requirements for a monitoring plan that provides evidence of cleanroom performance over time.

  1. MeasureFixed locations at a fixed frequency
  2. RecordTogether with occupancy state and staffing
  3. AssessAgainst limits for follow-up
  4. InvestigateWhen a limit is exceeded
  5. AdjustAnd measure again after changes
The monitoring plan in the case
ElementContent
Fixed locationsAt assembly areas and the packing station
FrequencySet according to risk and process changes
RecordingMeasurements together with occupancy state and staffing
LimitsDefined limits for follow-up and investigation
Extra measurementAfter changes to ventilation, cleaning, production flow or layout
Periodic reviewAre the locations and frequency still relevant?

Scope

What a particle measurement does not show

Particle counting documents the concentration of airborne particles at the sizes included in the measurement. It says nothing about the particles' material, chemical content or biological nature.

An ISO class is not an overall approval of the process, a guarantee of product quality or documentation of GMP compliance either.

  • ShowsAirborne particles

    Number per m³ at the measured sizes

    ISO 14644-1
  • Needs other methodsChemical air contamination

    Gases and molecular contamination

    ISO 14644-8
  • Needs other methodsParticles on surfaces

    Cleanliness of work surfaces and equipment

    ISO 14644-9
  • Needs other methodsMicroorganisms

    Viable particles and microbiological conditions

    Microbiological methods

Our service

How we work with particle control

We organise particle control according to ISO 14644, from the test basis to a monitoring plan your operation can live with. The measurements and reports are uploaded to your My page.

If the measurements show that the area needs cleaning, we carry out the technical cleaning and measure again afterwards.

  1. 01Test basisClass, particle sizes, occupancy state and locations
  2. 02BaselineClassification and diagnostic locations
  3. 03SourcesReview with operations and quality
  4. 04ImprovementsMeasures and technical cleaning
  5. 05RepeatSame locations and same set-up
  6. 06MonitoringA plan to ISO 14644-2
Technicians in cleanroom garments during technical cleaning of a new data hall
Technical cleaning of a data hall before commissioning.
What you get
DeliverableContent
Classification reportClass, occupancy state, locations, sample volume and result per location
Source assessmentFluctuations linked to activities, with prioritised measures
Repeat measurementBefore and after at the same locations
Monitoring planLocations, frequency, limits and when to measure extra
My pageAll reports in one place, see Compliance & documentation

In data centres and server rooms we combine the particle measurement with technical data centre cleaning and server room cleaning.

Questions

Frequently asked questions

Answers to what we are asked most often about ISO 14644 and particle measurement.

What is ISO 14644-1?

ISO 14644-1 is the part of the ISO 14644 series that classifies air cleanliness by the concentration of airborne particles. It defines nine classes from ISO Class 1 to ISO Class 9 and describes how sampling locations and sample volume are determined. The current edition is from 2015.

How many sampling locations are needed?

The minimum number follows from the room's area according to Table A.1 in ISO 14644-1. A room of up to 352 m² requires 24 locations, and a room of up to 1,000 m² requires 27. Critical spots can require extra locations in addition to the distributed ones.

Which ISO class should a data centre have?

In data centres, ISO Class 8 is the usual target after technical cleaning and before handover. The requirement depends on the equipment supplier's and the owner's requirements, so the class is agreed as part of the test basis.

What is the difference between classification and monitoring?

Classification to ISO 14644-1 documents cleanliness during one measurement. Monitoring to ISO 14644-2 provides ongoing evidence that the area continues to meet the class as operation changes.

Can a particle measurement show whether the air is free of bacteria?

No. A particle counter counts particles at specific sizes, but does not distinguish between viable and non-viable particles. Microbiological conditions require other methods.

How long must each location be sampled?

The sample volume must be large enough to statistically expect at least 20 particles at the class limit for the largest particle size, and at least 2 litres for at least 1 minute. The cleaner the class, the longer the sample.

Engineering continuity

Do you know where the particles come from?

We classify your area to ISO 14644, find the sources and build a monitoring plan that detects changes in time.