Bluecircle · Battery racks

Battery cabinetsFor your blocks, your number and your room

A battery cabinet is the safe way to keep the UPS batteries right next to the UPS system: closed steel, lockable doors and no exposed live parts – even in rooms other people use. We have pre-calculated cabinet solutions for 158 battery types from 1 to 12 strings, and if no standard cabinet fits, we build it to measure.

from €870per cabinet, excl. VAT

Excl. delivery and installation

Battery cabinets
Example: ZincFive BC 2. Photo: ZincFive
158Battery types pre-calculated
1–12Strings per solution
900–2,200 mmCabinet height
400–800 mmCabinet depth

Anything is possible

No battery bank is too small or too large

We have calculated almost 1,900 cabinet sizes for the blocks we supply – from compact 12 V blocks to the largest VRLA blocks. For every combination we know the dimensions, weight and floor load, so you get the smallest solution that holds your battery bank.

Every block size

From compact 12 V blocks to heavy high-capacity blocks. The cabinet is sized to the block’s dimensions and weight.

Any number of blocks

One string or twelve – and more cabinets side by side as the battery bank grows. If your UPS uses a different number of blocks per string, we build for that.

Built to measure

If the cabinet has to fit a specific height, width or depth in the room, we adapt it.

Complete cabinet systems

Nickel-zinc and lithium in their own cabinet

Besides steel cabinets for VRLA blocks, we supply complete cabinet systems in which batteries, monitoring and the battery breaker are built together at the factory.

Samsung SDI battery cabinet with lithium-ion modules
Samsung SDI battery cabinet with lithium-ion modules

Safety

Locked – even in rooms other people use

Under EN IEC 62485-2, batteries with a nominal voltage above 120 V DC must be located with restricted access, secured by a lock. A locked cabinet meets this without a separate battery room, so the batteries can stand right next to the UPS system.

Cabinet, rack or internal batteries?

The comparison, the room requirements and our sizing principles are in Battery rack, battery cabinet or internal batteries?

Bluecircle

Delivered, installed and ready to run

Delivery and installationWe deliver the cabinet, install the blocks and cable it to the battery switchboard.
Floor loadWe state the calculated floor load for the solution so the floor can be assessed in advance.
UPS battery testingMeasurement of every block and capacity testing with a load bank.Read more →Service agreementsPlanned service and guaranteed response time of 2, 4, 8 or 24 hours.Read more →

Tell us the block and the number – we will find the cabinet

Send us the UPS type, the battery block and the number of blocks you need. We will come back with a cabinet solution, dimensions and price.

+45 7012 1317kontakt@blue-circle.dkGet a quote