Bluecircle · Battery racks

Battery racksFrom one string to the whole battery room

When the battery bank is large or the blocks are heavy, a rack is the most space-efficient solution. The racks are built in steel for the chosen block and the room’s dimensions – on one or several tiers and in the length the room allows. We have more than 9,700 pre-calculated rack variants for 157 battery types from 1 to 12 strings.

from €468per rack, excl. VAT

Excl. delivery and installation

Battery racks
Battery rack on three tiers
157Battery types pre-calculated
1–12Strings per solution
Up to 15 mIn one rack
290–2,670 mmRack height

Anything is possible

The rack follows the block and the room

The room’s length, depth and ceiling height decide the layout: long racks on few tiers, short racks on several tiers or several racks side by side. For every solution we know the dimensions, weight and floor load.

Rack on several tiers, ready for the blocks
Rack on several tiers, ready for the blocks

Every block size

From compact 12 V blocks to the largest and heaviest blocks that will not fit in a cabinet.

Any number of blocks

One string or twelve – and more racks as the battery bank grows. If your UPS uses a different number of blocks per string, we build for that.

Built for the room

Tiers, length and depth are adapted so the racks make the most of the room and leave the required aisles.

The battery room

Locked room, ventilation and space

A rack is open, so the battery room is the protection. Under EN IEC 62485-2, batteries above 120 V DC must be located with restricted access, secured by a lock, and the room must be ventilated. We plan the racks with working distances in front of the blocks and state the floor load.

Cabinet, rack or internal batteries?

The comparison, the room requirements and our sizing principles are in Battery rack, battery cabinet or internal batteries?

Battery room with battery racks, installed by Bluecircle
Battery room with battery racks, installed by Bluecircle

Bluecircle

Assembled and installed on site

InstallationWe assemble the racks in the battery room, install the blocks and cable them to the battery switchboard.
Floor loadWe state the calculated floor load for the solution so the floor can be assessed in advance.
UPS battery testingMeasurement of every block and capacity testing with a load bank.Read more →Service agreementsPlanned service and guaranteed response time of 2, 4, 8 or 24 hours.Read more →

Tell us the block and the room – we will build the rack

Send us the battery block, the number of blocks and the room’s dimensions. We will come back with a layout, dimensions and price.

+45 7012 1317kontakt@blue-circle.dkGet a quote